Skip to content
Çilek Havuz

Control Panels

Electrical Control Panel, Pool Pump Control Panel.

The Electrical Control Panel is a pool pump control panel that manages the overload protection and operating hours of a pool pump. Çilek Havuz supplies Control Panel through quotes and as part of its projects. Four Types cover the 1.6-10 A range: A, B, C and D. It comes in four versions: pump protection, pump and lighting, and single-phase or three-phase underwater light protection. The enclosure is IP65 and includes a 24-hour programming timer.

Datasheet

CH-POM-0016-01

Electrical Control Panel seen at an angle, white body
Current range
1.6-10A, four Types
List price
From €278.25 + VAT

Prices are list prices dated 16.06.2026, excluding VAT.

Before you choose

Suitable pool and installation

Models and price

16 models

List price €278.25 - €498.75 excl. VAT

Lowest list price: Type A - Pump protection

List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.

Open the spec sheet
See all models and technical data

Compatibility and connections

Current range
1.6-10 A, four Types
Supply
Single-phase or three-phase
Protection class
IP65
Timing
24 hours, Auto/0/Manual

// Models

Electrical Control Panel models, with list prices and technical data.

16 products

  • Type A - Pump protection

    Recommended

    Code CH-POM-0016-01

    Current
    1.6 - 2.5 A
    Pump power range (single-phase 230 V)
    1/4 HP
    App
    Pump overload protection
    Price€278.25 + VAT

    Type A - Pump protection

    Code CH-POM-0016-01

    €278.25 + VAT

    Manufacturer Code
    25717
    App
    Pump overload protection
    Current
    1.6 - 2.5 A
    Pump power range (single-phase 230 V)
    1/4 HP
    Pump power range (three-phase 400 V)
    3/4 - 1 HP
    Pump power range (three-phase 230 V)
    1/2 HP
    Voltage
    220-240 (1-phase) / 380-415 (3-phase) / 220-230 (3-phase) V
    Frequency
    50 / 60 Hz
    Lamp output
    -
    Control
    24-hour programming clock; 3-position switch (Auto / 0 / Manual); thermal overload protection and contactor
    Protection Class (IP)
    IP65
    Certification
    EN 16582-1:2015
    Weight
    1.9 kg
  • Type B - Pump protection

    Code CH-POM-0016-02

    Current
    2.5 - 4 A
    Pump power range (single-phase 230 V)
    1/2 HP
    App
    Pump overload protection
    Price€278.25 + VAT
  • Type C - Pump protection

    Code CH-POM-0016-03

    Current
    4 - 6.3 A
    Pump power range (single-phase 230 V)
    3/4 - 1 HP
    App
    Pump overload protection
    Price€283.50 + VAT
  • Type D - Pump protection

    Code CH-POM-0016-04

    Current
    6 - 10 A
    Pump power range (single-phase 230 V)
    1.5 HP
    App
    Pump overload protection
    Price€278.25 + VAT
  • Type A - Pump + lighting

    Code CH-POM-0016-05

    Current
    1.6 - 2.5 A
    Pump power range (single-phase 230 V)
    1/4 HP
    App
    Pump overload protection + lighting control
    Price€315 + VAT
  • Type B - Pump + lighting

    Code CH-POM-0016-06

    Current
    2.5 - 4 A
    Pump power range (single-phase 230 V)
    1/2 HP
    App
    Pump overload protection + lighting control
    Price€315 + VAT
  • Type C - Pump + lighting

    Code CH-POM-0016-07

    Current
    4 - 6.3 A
    Pump power range (single-phase 230 V)
    3/4 - 1 HP
    App
    Pump overload protection + lighting control
    Price€315 + VAT
  • Type D - Pump + lighting

    Code CH-POM-0016-08

    Current
    6 - 10 A
    Pump power range (single-phase 230 V)
    1.5 HP
    App
    Pump overload protection + lighting control
    Price€315 + VAT
  • Type A - Pump + single-phase underwater light

    Code CH-POM-0016-09

    Current
    1.6 - 2.5 A
    Pump power range (single-phase 230 V)
    1/4 HP
    App
    Pump overload protection + underwater light with differential protection (single-phase)
    Price€420 + VAT
  • Type B - Pump + single-phase underwater light

    Code CH-POM-0016-10

    Current
    2.5 - 4 A
    Pump power range (single-phase 230 V)
    1/2 HP
    App
    Pump overload protection + underwater light with differential protection (single-phase)
    Price€420 + VAT
  • Type C - Pump + single-phase underwater light

    Code CH-POM-0016-11

    Current
    4 - 6.3 A
    Pump power range (single-phase 230 V)
    3/4 - 1 HP
    App
    Pump overload protection + underwater light with differential protection (single-phase)
    Price€420 + VAT
  • Type D - Pump + single-phase underwater light

    Code CH-POM-0016-12

    Current
    6 - 10 A
    Pump power range (single-phase 230 V)
    1.5 HP
    App
    Pump overload protection + underwater light with differential protection (single-phase)
    Price€420 + VAT
  • Type A - Pump + three-phase underwater light

    Code CH-POM-0016-13

    Current
    1.6 - 2.5 A
    Pump power range (single-phase 230 V)
    1/4 HP
    App
    Pump overload protection + underwater light with differential protection (three-phase)
    Price€498.75 + VAT
  • Type B - Pump + three-phase underwater light

    Code CH-POM-0016-14

    Current
    2.5 - 4 A
    Pump power range (single-phase 230 V)
    1/2 HP
    App
    Pump overload protection + underwater light with differential protection (three-phase)
    Price€498.75 + VAT
  • Type C - Pump + three-phase underwater light

    Code CH-POM-0016-15

    Current
    4 - 6.3 A
    Pump power range (single-phase 230 V)
    3/4 - 1 HP
    App
    Pump overload protection + underwater light with differential protection (three-phase)
    Price€498.75 + VAT
  • Type D - Pump + three-phase underwater light

    Code CH-POM-0016-16

    Current
    6 - 10 A
    Pump power range (single-phase 230 V)
    1.5 HP
    App
    Pump overload protection + underwater light with differential protection (three-phase)
    Price€498.75 + VAT

// 01 · Technical table

Electrical Control Panel technical values

Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.

Electrical Control Panel technical values · 16 models
SpecificationValue
Manufacturer Code25717 / 25718 / 25719 / 25720 / 25721 / 25722 / 25723 / 25724 / 25725 / 25726 / 25727 / 25728 / 25729 / 25730 / 25731 / 25732
AppPump overload protection / Pump overload protection + lighting control / Pump overload protection + underwater light with differential protection (single-phase) / Pump overload protection + underwater light with differential protection (three-phase)
Current1.6 - 2.5 A / 2.5 - 4 A / 4 - 6.3 A / 6 - 10 A
Pump power range (single-phase 230 V)1/4 HP / 1/2 HP / 3/4 - 1 HP / 1.5 HP
Pump power range (three-phase 400 V)3/4 - 1 HP / 1.5 - 2 HP / 3 HP / 4 HP
Pump power range (three-phase 230 V)1/2 HP / 3/4 - 1 HP / 1.5 HP / 2 - 3 HP
Voltage220-240 (1-phase) / 380-415 (3-phase) / 220-230 (3-phase) V
Frequency50 / 60 Hz
Lamp outputProtected 230 V 10 A outlet (single-phase) / Protected 230 V 10 A outlet (three-phase) (on some models)
Control24-hour programming clock; 3-position switch (Auto / 0 / Manual); thermal overload protection and contactor
Protection Class (IP)IP65
CertificationEN 16582-1:2015
Weight1.9 kg / 2.3 kg / 2.1 kg / 2.4 kg

// 02 · Use

Users and applications

The Electrical Control Panel protects and times a single speed pool pump from a single point. The Type is chosen by the current of the pump motor: A 1.6-2.5 A, B 2.5-4 A, C 4-6.3 A, D 6-10 A. If lighting or an underwater light is also to be managed from the same panel, the corresponding version is chosen. For single speed pumps such as Sena and Verdon ES, the motor current is checked against these ranges.

  • Thermal overload protection of a single speed pump
  • Daily filtration time with 24-hour timing
  • Lighting control together with the pump (second version)
  • Underwater light output with single-phase or three-phase differential protection

// 03 · Installation and compatibility

Installation and compatible equipment

The panel is fixed to the wall between the pump and the supply line; a set of four screws and wall plugs comes in the pack. The input must match the rated voltage of the pump: 220-240 V single-phase, 380-415 V or 220-230 V three-phase. The pump cable is connected to the contactor output. The electrical diagram and wiring diagram are supplied with the panel.

  1. Type A, B, C or D is determined by the current of the pump motor.
  2. The panel is fixed to the wall with four screws and wall plugs.
  3. The supply line is connected to the input terminals that match the voltage.
  4. The pump output is connected, the switch is set to Auto and the timer is set.

// 04 · Maintenance

Maintenance checkpoints

Routine checking of the panel means reviewing the timer and switch behind the transparent cover. The cover is lockable; the supply is switched off before it is opened. The timer setting is verified by checking whether it matches the daily running time. If thermal protection activates frequently, the pump current and the selected Type are checked together.

  • The supply is switched off before working inside the panel.
  • The time and programme shown on the programming timer are checked.
  • The cover is kept closed and locked; this is how the IP65 rating is maintained.
  • If thermal protection trips repeatedly, the pump current is measured.

// 05 · Information form

Request information on this product

Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form

Electrical Control Panel

Product
Electrical Control Panel
Category
Pool Mechanical Equipment
Number of models
16
Code
CH-POM-0016-01 ... CH-POM-0016-16

Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.

Your contact details

Name, surname, phone and email are enough.

Your personal data is processed in line with our Privacy Notice (KVKK).

// 06 · Reviews

Electrical Control Panel reviews

If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.

Average rating

0/5

Verified reviews: 0

5 out of 5 stars
0
4 out of 5 stars
0
3 out of 5 stars
0
2 out of 5 stars
0
1 out of 5 stars
0

Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.

There are no verified reviews for this product yet. Be the first to write one.

Write a review

Write a review

Once verified, your review is published with your name and city. Your email or phone number is never published.

Your rating

What is your review about?

Not published; used only to verify your review.

Your personal data is processed in line with our Privacy Notice (KVKK).

// 07 · Related products

Products considered together

First the products in the same family, then the power, connection and control parts it needs to run, and finally the complementary products usually chosen with it.

// 09 · Guides

Selection and installation guides

These articles cover the calculations, comparisons and installation details considered when choosing and installing Electrical Control Panel.

// 10 · Data sheet and catalogue

Printable documents

The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.

Product details
Electrical Control Panel
Model
16
Code
CH-POM-0016-01 - CH-POM-0016-16

// 11 · Design and catalogues

Set up your project on screen first, then review the products in our catalogues.

In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.

Long villa pool with a travertine edge and olive trees at sunsetPool

Design studio

Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.

Where would you like to start?

Next step

Let us discuss your project in the way that suits you best.

You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.

  • Get a Quote

    Send us your dimensions and expectations in writing.

  • Online presentation

    Video project presentation

  • On-site survey

    Inspection at your project site

// 12 · Company & Contact

To talk about your project, call or write to us.

Legal Name

Çilek Havuz

Founded

1998 · Istanbul

Head Office

Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul

Service Area

All of Türkiye · exports to 14 countries

Branches

Kyrgyzstan · Egypt · Algeria · Iraq

Showroom

Plan a showroom visit

At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.

Working Hours

  • Monday – Friday · 08:00 – 17:30
  • Saturday · 08:00 – 12:30
  • Closed on Sunday
Directions

Questions

About Electrical Control Panel: frequently asked questions

Çilek Havuz Corporate

Pool & Wellness Engineering

Response Time
Same day
Channels
Phone · Email · WhatsApp

If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.

+90 216 475 39 37

The Type is chosen by the current range and power of the pump motor. For a single-phase 230 V pump, Type A is for 1/4 HP, Type B for 1/2 HP, Type C for 3/4 to 1 HP and Type D for 1.5 HP. The current ranges are 1.6-2.5, 2.5-4, 4-6.3 and 6-10 A respectively.

Çilek Havuz Corporate

The first version provides pump overload protection only. The second version adds lighting control. The third and fourth versions provide an underwater light output with differential protection; one is single-phase and the other three-phase. Each version comes in four Types from A to D. The choice depends on which additional output is wanted from the panel.

Çilek Havuz Corporate

Yes, the input can be 220-240 V single-phase, 380-415 V three-phase or 220-230 V three-phase. The pump power varies with the phase: Type C suits a 3 HP pump on 400 V three-phase and a 1.5 HP pump on 230 V three-phase. The phase and voltage of the pump are the basis of the choice.

Çilek Havuz Corporate

This panel provides pump protection, optional lighting control and a light output with differential protection. The LED/Underwater Light model has a 12 V output and is designed for 1 set of LED lights or a single 12 V 315 light. For an installation centred on lighting, the second model is chosen.

Çilek Havuz Corporate

The panel sets the operating hours of the pump with a 24-hour programming timer. The three-position switch has Auto, 0 and Manual positions. The contactor switches the pump on, while thermal overload protection protects the pump against a rise in current. In the Auto position the pump follows the timer; in the Manual position it runs independently of the timer.

Çilek Havuz Corporate

Yes, Sena is a single speed pump and can be supplied from this panel. Sena single-phase models run on 230 V and three-phase models on 230-400 V. The same approach applies to single speed pumps such as Verdon ES. The Type is chosen by the ampere rating of the pump motor.

Çilek Havuz Corporate

The enclosure has protection class IP65. The pump protection only version weighs 1.9 kg, the lighting version 2.3 kg, the single-phase light protection version 2.1 kg and the three-phase light protection version 2.4 kg. The frequency is 50 and 60 Hz. All four versions come in the same white enclosure.

Çilek Havuz Corporate