Pool Filters
Olot Bobbin-Wound Filter, Filament Wound Filter with Nozzle Plate.
The Olot Filament Wound Filter is a filament wound pool filter with a nozzle plate, fitted on the filter line of public pools. Çilek Havuz supplies Olot through quotes and as part of its projects. Its seven body diameters range from Ø1050 to 2200 mm, the bed height is 1.2 m and the filtration velocity is 30 m³/h/m². Flow ranges from 25 to 114 m³/h. Each size is sold in 2.5 bar and 4 bar classes. A Ø400 mm lid and side manhole are standard.
CH-FLT-0004-01

- Body Diameter
- 1050-2200mm
- Flow Rate
- 25-114m³/h
- System
- Nozzle plate
- List price
- From €14,910 + VAT
Prices are list prices dated 16.06.2026, excluding VAT.
Suitable pool and installation
Models and price
14 models
List price €14,910 - €51,450 excl. VAT
Lowest list price: Ø1050mm · 1.2 m bed · 2.5bar
List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.
See all models and technical dataCompatibility and connections
- System
- Nozzle plate
- Body diameter
- Ø1050-2200 mm
- Filtration velocity
- 30 m³/h/m²
- Pressure class
- 2.5 or 4 bar
// Models
Olot Bobbin-Wound Filter models, with list prices and technical data.
14 products
Ø1050mm · 1.2 m bed · 2.5bar
RecommendedCode CH-FLT-0004-01
- Body Diameter
- 1050 mm
- Flow Rate
- 25 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€14,910 + VAT- Manufacturer Code
- 07355-120
- Body Diameter
- 1050 mm
- Filtration Area
- 0.87 m²
- Filtration velocity
- 30 m³/h/m²
- Flow Rate
- 25 m³/h
- Connection
- Ø110 mm
- Max. Operating Pressure
- 2.5 bar
- Filter bed height
- 1.2 m
- Top lid diameter
- 400 mm
- Body Material
- Isophthalic polyester and fibreglass (filament-wound)
- Certification
- DIN 19605 / 19643
Ø1050mm · 1.2 m bed · 4bar
Code CH-FLT-0004-02
- Body Diameter
- 1050 mm
- Flow Rate
- 25 m³/h
- Max. Operating Pressure
- 4 bar
Price€15,540 + VATØ1200mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-03
- Body Diameter
- 1200 mm
- Flow Rate
- 33 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€19,950 + VATØ1200mm · 1.2 m bed · 4bar
Code CH-FLT-0004-04
- Body Diameter
- 1200 mm
- Flow Rate
- 33 m³/h
- Max. Operating Pressure
- 4 bar
Price€21,000 + VATØ1400mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-05
- Body Diameter
- 1400 mm
- Flow Rate
- 46 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€27,825 + VATØ1400mm · 1.2 m bed · 4bar
Code CH-FLT-0004-06
- Body Diameter
- 1400 mm
- Flow Rate
- 46 m³/h
- Max. Operating Pressure
- 4 bar
Price€24,465 + VATØ1600mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-07
- Body Diameter
- 1600 mm
- Flow Rate
- 60 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€27,825 + VATØ1600mm · 1.2 m bed · 4bar
Code CH-FLT-0004-08
- Body Diameter
- 1600 mm
- Flow Rate
- 60 m³/h
- Max. Operating Pressure
- 4 bar
Price€33,075 + VATØ1800mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-09
- Body Diameter
- 1800 mm
- Flow Rate
- 76 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€31,185 + VATØ1800mm · 1.2 m bed · 4bar
Code CH-FLT-0004-10
- Body Diameter
- 1800 mm
- Flow Rate
- 76 m³/h
- Max. Operating Pressure
- 4 bar
Price€33,075 + VATØ2000mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-11
- Body Diameter
- 2000 mm
- Flow Rate
- 94 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€37,800 + VATØ2000mm · 1.2 m bed · 4bar
Code CH-FLT-0004-12
- Body Diameter
- 2000 mm
- Flow Rate
- 94 m³/h
- Max. Operating Pressure
- 4 bar
Price€40,425 + VATØ2200mm · 1.2 m bed · 2.5bar
Code CH-FLT-0004-13
- Body Diameter
- 2200 mm
- Flow Rate
- 114 m³/h
- Max. Operating Pressure
- 2.5 bar
Price€46,620 + VATØ2200mm · 1.2 m bed · 4bar
Code CH-FLT-0004-14
- Body Diameter
- 2200 mm
- Flow Rate
- 114 m³/h
- Max. Operating Pressure
- 4 bar
Price€51,450 + VAT
// 01 · Technical table
Olot Bobbin-Wound Filter technical values
Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.
| Specification | Value |
|---|---|
| Manufacturer Code | 07355-120 / 07355-120 PR 04 / 07356-120 / 07356-120 PR 04 / 07447-120 / 07447-120 PR 04 / 07357-120 / 07357-120 PR 04 / 07448-120 / 07448-120 PR 04 / 07358-120 / 07358-120 PR 04 / 56934-120 / 56934-120 PR 04 |
| Body Diameter | 1050 mm / 1200 mm / 1400 mm / 1600 mm / 1800 mm / 2000 mm / 2200 mm |
| Filtration Area | 0.87 m² / 1.13 m² / 1.54 m² / 2.01 m² / 2.54 m² / 3.14 m² / 3.80 m² |
| Filtration velocity | 30 m³/h/m² |
| Flow Rate | 25 m³/h / 33 m³/h / 46 m³/h / 60 m³/h / 76 m³/h / 94 m³/h / 114 m³/h |
| Connection | Ø110 mm / Ø125 mm / Ø140 mm / Ø160 mm / Ø200 mm / Ø225 mm |
| Max. Operating Pressure | 2.5 bar / 4 bar |
| Filter bed height | 1.2 m |
| Top lid diameter | 400 mm |
| Body Material | Isophthalic polyester and fibreglass (filament-wound) |
| Certification | DIN 19605 / 19643 |
// 02 · Use
Users and applications
Olot is chosen for public pool lines that need a system in which the filter bed rests on a nozzle plate. There is a single velocity option, 30 m³/h/m². Size selection therefore depends directly on flow: the Ø1050 mm body delivers 25 m³/h and the Ø2200 mm body 114 m³/h. For high flows, the connection diameter goes up to Ø225 mm.
- Public pools that need a nozzle plate filter system
- Filtration lines working at a single velocity of 30 m³/h/m²
- Pipework using connection diameters between Ø110 and Ø225 mm
- Lines that need a 2.5 bar or 4 bar pressure class
// 03 · Installation and compatibility
Installation and compatible equipment
Olot is fitted between the pool pump and the pool return line. A pressure gauge, air bleed valve and water drain valve come with the body. A Ø400 mm top lid and side manhole are standard. The valve manifold and filter media are not included in the pack and are supplied separately. The connection diameter is Ø110-Ø225 mm depending on the body.
- The body is placed on a level, load-bearing base in the plant room.
- The valve manifold is fitted to the body separately.
- The pump and return lines are connected according to the connection diameter of the model.
- The media is filled through the Ø400 mm lid onto the nozzle plate; Active Glass Media can be chosen for this purpose.
// 04 · Maintenance
Maintenance checkpoints
Routine work on Olot is reading the operating pressure on the pressure gauge. The pressure is kept below the 2.5 bar or 4 bar class. The air bleed valve is for releasing air from the filter and the water drain valve for emptying the body. The side manhole and Ø400 mm lid are opened to inspect the media only when the filter is out of service.
- The gauge reading is monitored during operation.
- The air bleed valve and water drain valve are checked.
- The seats of the side manhole and Ø400 mm lid are kept clean when they are closed.
- The connections are checked for leaks.
// 05 · Information form
Request information on this product
Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form
Olot Bobbin-Wound Filter
- Product
- Olot Bobbin-Wound Filter
- Category
- Pool Mechanical Equipment
- Number of models
- 14
- Code
- CH-FLT-0004-01 ... CH-FLT-0004-14
Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.
Your contact details
Name, surname, phone and email are enough.
// 06 · Reviews
Olot Bobbin-Wound Filter reviews
If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.
Average rating
0/5
Verified reviews: 0
- 5 out of 5 stars
- 0
- 4 out of 5 stars
- 0
- 3 out of 5 stars
- 0
- 2 out of 5 stars
- 0
- 1 out of 5 stars
- 0
Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.
There are no verified reviews for this product yet. Be the first to write one.
Write a review// 07 · Related products
Products considered together
First the products in the same family, then the power, connection and control parts it needs to run, and finally the complementary products usually chosen with it.
// 08 · Services
Work carried out with this product
Olot Bobbin-Wound Filter can be purchased on its own or installed as part of a pool construction or maintenance project.
- Swimming Pool ConstructionReinforced-concrete, prefabricated and infinity swimming pools, built turnkey for villa, residential and commercial projects.
- Infinity PoolsPools that open onto the view, with water spilling over the edge into a balance tank.
- Prefabricated PoolsFast-install modular prefabricated pool systems.
- Pool MaintenanceWater chemistry, equipment and periodic maintenance.
- Pool ConsultingExpert consulting on project, materials and budget.
- Yakacık Msy Yapı · Villa PoolYakacık, Istanbul
// 09 · Guides
Selection and installation guides
These articles cover the calculations, comparisons and installation details considered when choosing and installing Olot Bobbin-Wound Filter.
// 10 · Data sheet and catalogue
Printable documents
The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.
- Product details
- Olot Bobbin-Wound Filter
- Model
- 14
- Code
- CH-FLT-0004-01 - CH-FLT-0004-14
- Category
- Pool Mechanical Equipment
// 11 · Design and catalogues
Set up your project on screen first, then review the products in our catalogues.
In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.
PoolDesign studio
Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.
Where would you like to start?
Product catalogues
Models, technical sheets and list prices of our product groups are on the category pages.
Next step
Let us discuss your project in the way that suits you best.
You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.
Get a Quote
Send us your dimensions and expectations in writing.
Online presentation
Video project presentation
On-site survey
Inspection at your project site
// 12 · Company & Contact
To talk about your project, call or write to us.
Legal Name
Çilek Havuz
Founded
1998 · Istanbul
Head Office
Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul
Service Area
All of Türkiye · exports to 14 countries
Branches
Kyrgyzstan · Egypt · Algeria · Iraq
Showroom
Plan a showroom visit
At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.
Working Hours
- Monday – Friday · 08:00 – 17:30
- Saturday · 08:00 – 12:30
- Closed on Sunday
Questions
About Olot Bobbin-Wound Filter: frequently asked questions
Çilek Havuz Corporate
Pool & Wellness Engineering
- Response Time
- Same day
- Channels
- Phone · Email · WhatsApp
If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.
+90 216 475 39 37The size is chosen by the flow the line requires; the velocity is fixed at 30 m³/h/m². Ø1050 mm delivers 25 m³/h, Ø1200 mm 33, Ø1400 mm 46, Ø1600 mm 60, Ø1800 mm 76, Ø2000 mm 94 and Ø2200 mm 114 m³/h. The filter area is between 0.87 m² and 3.80 m².
Çilek Havuz Corporate
The difference lies in the filter system, velocity options and connection diameter. Olot is sold only with a nozzle plate system and at 30 m³/h/m². Oslo comes at velocities of 30 and 40 m³/h/m². On the same Ø1050 mm body, Olot uses a Ø110 and Oslo a Ø75 mm connection. Both have a bed height of 1.2 m.
Çilek Havuz Corporate
The filter bed rests on the nozzle plate inside the body. All Olot models come with this system. A pressure gauge, air bleed valve and water drain valve are supplied with the pack. The media and valve manifold are separate from the pack. For media, a product such as Active Glass Media is considered separately.
Çilek Havuz Corporate
Olot comes with a Ø400 mm filter lid and side manhole as standard. The media is filled through the Ø400 mm lid, and the side manhole is used to empty the media. The body is made of isophthalic polyester and fibreglass by the filament winding method. The lid and manhole are opened while the filter is out of service.
Çilek Havuz Corporate
The connection diameter increases with the body. It is Ø110 on the Ø1050 mm body, Ø125 on the Ø1200 mm body, Ø140 on the Ø1400 mm body and Ø160 mm on the Ø1600 mm body. The Ø1800 mm body uses a Ø200 mm connection. Both the Ø2000 and Ø2200 mm bodies have a connection diameter of Ø225 mm.
Çilek Havuz Corporate
The PR 04 suffix indicates the 4 bar pressure class. On the Ø1050 mm body, the code of the 2.5 bar model is 07355-120 and that of the 4 bar model is 07355-120 PR 04. Filter area, flow and connection diameter stay the same on both versions. If the line pressure exceeds 2.5 bar, the 4 bar version is chosen.
Çilek Havuz Corporate
The filter bed of Olot is 1.2 m high. The body is made of isophthalic polyester and fibreglass and is filament wound. This construction is used in both the 2.5 bar and 4 bar classes. The bed is filled with filter media on site; the media and valve manifold are not included in the filter code.
Çilek Havuz Corporate