Pool Disinfection Systems
Amperometric Electrode & Calibration Solution, Measurement Consumable.
Amperometric Electrode and Calibration Solution is a group of measurement consumables that keeps free chlorine, pH and ORP measurement running on control panels. Çilek Havuz supplies Amperometric Electrode through quotes and as part of its projects. The group includes a free chlorine electrode, ECC1 electrolyte gel, CL.01.02 membrane, and pH and ORP electrodes. For calibration, pH 7.0 green, pH 4.0 red and 470 mV solutions are supplied in 30 mL bottles.
CH-DEZ-0041-06

- Weight
- 0.02-0.22kg
- Measuring method
- Amperometric chlorine, potentiometric pH and ORP
- List price
- From €29.40 + VAT
Prices are list prices dated 16.06.2026, excluding VAT.
Suitable pool and installation
Models and price
8 models
List price €29.40 - €2,940 excl. VAT
Lowest list price: pH 7.0 solution 30mL (green)
List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.
See all models and technical dataCompatibility and connections
- Measuring method
- Amperometric chlorine, potentiometric pH and ORP
- Measured value
- Free chlorine (ppm), pH, ORP (mV)
- Calibration
- pH 7.0 and pH 4.0 buffer, 470 mV reference
- Bottle volume
- 30 mL
- Scope
- 8 items: 5 electrode parts, 3 solutions
// Models
Amperometric Electrode & Calibration Solution models, with list prices and technical data.
8 products
Free chlorine electrode
Code CH-DEZ-0041-01
- Weight
- 0.22 kg
Price€2,940 + VATECC1 electrolyte / gel
Code CH-DEZ-0041-02
- Weight
- 0.07 kg
Price€220.50 + VATCL.01.02 membrane
Code CH-DEZ-0041-03
- Weight
- 0.02 kg
Price€315 + VATpH electrode
Code CH-DEZ-0041-04
- Weight
- 0.20 kg
Price€220.50 + VATORP electrode
Code CH-DEZ-0041-05
- Weight
- 0.20 kg
Price€624.75 + VATpH 7.0 solution 30mL (green)
RecommendedCode CH-DEZ-0041-06
- Weight
- 0.053 kg
Price€29.40 + VATpH 4.0 solution 30mL (red)
Code CH-DEZ-0041-07
- Weight
- 0.058 kg
Price€29.40 + VAT470mV solution 30mL
Code CH-DEZ-0041-08
- Weight
- 0.060 kg
Price€43.05 + VAT
// 01 · Technical table
Amperometric Electrode & Calibration Solution technical values
Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.
| Specification | Value |
|---|---|
| Manufacturer Code | 60645 / 60646 / 60647 / 60648 / 60649 / 60618 / 60632 / 60633 |
| Weight | 0.22 kg / 0.07 kg / 0.02 kg / 0.20 kg / 0.053 kg / 0.058 kg / 0.060 kg |
// 02 · Use
Users and applications
Amperometric Electrode and Calibration Solution is intended for facilities using a control panel that measures chlorine and pH automatically. Measuring electrodes age over time and the reading drifts. A drifting reading leads the panel to dose incorrectly. The replacement part is chosen by the value the panel measures: free chlorine, pH or ORP.
- Panels measuring free chlorine (ppm): free chlorine electrode, ECC1 gel, CL.01.02 membrane
- Panels measuring pH: pH electrode, pH 7.0 and pH 4.0 solutions
- Panels measuring redox (ORP): ORP electrode and 470 mV solution
- Measuring lines where electrodes and solutions are renewed together
// 03 · Installation and compatibility
Installation and compatible equipment
The electrode is fitted in the measuring line of the control panel and its cable is connected to the corresponding input on the panel. The manufacturer's instructions for the panel are read before the replacement. Once the new electrode is fitted, calibration is carried out from the panel menu. The pH electrode is calibrated at two points: first pH 7.0, then pH 4.0. The ORP electrode is checked with the 470 mV solution.
- The value measured by the panel is identified and the part is chosen.
- The old electrode is removed and its cable is disconnected.
- On the free chlorine electrode, the membrane and ECC1 gel are renewed and the electrode is fitted.
- The pH electrode is calibrated with pH 7.0 and pH 4.0, the ORP electrode with 470 mV.
- The readings are compared with a manual water test.
// 04 · Maintenance
Maintenance checkpoints
Measuring electrodes need regular calibration for the panel to dose correctly. Calibration is repeated at the start of the season and whenever the reading departs from a manual test. On the free chlorine electrode, the membrane and ECC1 gel are changed periodically. The electrode tip is not left to dry out. Calibration solution is not poured back into the bottle after use.
- The electrode tip is rinsed with clean water before calibration.
- Used solution is not poured back into the bottle and the cap is closed straight away.
- If the membrane is scratched or dirty, the CL.01.02 membrane is renewed.
- During a long shutdown, the electrode tip is kept moist and not left dry.
// 05 · Information form
Request information on this product
Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form
Amperometric Electrode & Calibration Solution
- Product
- Amperometric Electrode & Calibration Solution
- Category
- Pool Disinfection Systems
- Number of models
- 8
- Code
- CH-DEZ-0041-01 ... CH-DEZ-0041-08
Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.
Your contact details
Name, surname, phone and email are enough.
// 06 · Reviews
Amperometric Electrode & Calibration Solution reviews
If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.
Average rating
0/5
Verified reviews: 0
- 5 out of 5 stars
- 0
- 4 out of 5 stars
- 0
- 3 out of 5 stars
- 0
- 2 out of 5 stars
- 0
- 1 out of 5 stars
- 0
Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.
There are no verified reviews for this product yet. Be the first to write one.
Write a review// 07 · Related products
Products considered together
First the products in the same family, then the power, connection and control parts it needs to run, and finally the complementary products usually chosen with it.
// 08 · Services
Work carried out with this product
Amperometric Electrode & Calibration Solution can be purchased on its own or installed as part of a pool construction or maintenance project.
- Pool MaintenanceWater chemistry, equipment and periodic maintenance.
- Swimming Pool ConstructionReinforced-concrete, prefabricated and infinity swimming pools, built turnkey for villa, residential and commercial projects.
- Pool ConsultingExpert consulting on project, materials and budget.
- Misk 30 · Multi-Unit PoolIstanbul
// 09 · Guides
Selection and installation guides
These articles cover the calculations, comparisons and installation details considered when choosing and installing Amperometric Electrode & Calibration Solution.
// 10 · Data sheet and catalogue
Printable documents
The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.
- Product details
- Amperometric Electrode & Calibration Solution
- Model
- 8
- Code
- CH-DEZ-0041-01 - CH-DEZ-0041-08
- Category
- Pool Disinfection Systems
// 11 · Design and catalogues
Set up your project on screen first, then review the products in our catalogues.
In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.
PoolDesign studio
Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.
Where would you like to start?
Product catalogues
Models, technical sheets and list prices of our product groups are on the category pages.
Next step
Let us discuss your project in the way that suits you best.
You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.
Get a Quote
Send us your dimensions and expectations in writing.
Online presentation
Video project presentation
On-site survey
Inspection at your project site
// 12 · Company & Contact
To talk about your project, call or write to us.
Legal Name
Çilek Havuz
Founded
1998 · Istanbul
Head Office
Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul
Service Area
All of Türkiye · exports to 14 countries
Branches
Kyrgyzstan · Egypt · Algeria · Iraq
Showroom
Plan a showroom visit
At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.
Working Hours
- Monday – Friday · 08:00 – 17:30
- Saturday · 08:00 – 12:30
- Closed on Sunday
Questions
About Amperometric Electrode & Calibration Solution: frequently asked questions
Çilek Havuz Corporate
Pool & Wellness Engineering
- Response Time
- Same day
- Channels
- Phone · Email · WhatsApp
If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.
+90 216 475 39 37The pH electrode is calibrated at two points: first with the pH 7.0 green solution, then with the pH 4.0 red solution. Both solutions come in 30 mL bottles. Calibration is started from the control panel menu. The electrode tip is rinsed with clean water between the two measurements so the solutions do not mix.
Çilek Havuz Corporate
The free chlorine electrode measures the free chlorine in the water directly in ppm. The ORP electrode measures the redox potential of the water in mV; chlorine is followed indirectly from this value. The ORP reading changes with pH and temperature. In public pools where chlorine is tracked as a figure, the free chlorine electrode is chosen.
Çilek Havuz Corporate
The ECC1 electrolyte gel and CL.01.02 membrane are the consumable parts of the free chlorine electrode. If the reading departs clearly from a manual chlorine test or calibration does not hold, both are renewed together. They are also changed when scratches, dirt or scale appear on the membrane. After the change, the electrode is calibrated again.
Çilek Havuz Corporate
The two parts do different jobs. The Salt Electrolysis Replacement Electrode is the plate in the electrolysis cell that produces chlorine from salt. Amperometric, pH and ORP electrodes only measure and are fitted in the measuring chamber of the control panel. If chlorine output has dropped, the cell electrode is checked; if the reading has drifted, the measuring electrode is checked.
Çilek Havuz Corporate
The electrodes are used in the measuring line of automatic control panels. The free chlorine electrode sits in panels that measure ppm, and the pH and ORP electrodes in panels that measure pH/ORP. AstralPool AP PR-200 Series, AstralPool Control Connect and AstralPool Poolguard / Poolwatch are panels of this kind. The electrode type and code on the panel are checked before ordering.
Çilek Havuz Corporate
Measuring electrodes age with use, and dirt and scale build up on the tip. On the free chlorine electrode, the membrane clogs and the electrolyte gel is used up. The panel then reads differently from the actual value and dosing drifts accordingly. With regular calibration and part renewal, the reading is kept close to a manual water test.
Çilek Havuz Corporate
The ORP electrode is calibrated with the 470 mV calibration solution. The solution comes in a 30 mL bottle. The pH 7.0 and pH 4.0 solutions belong to the pH electrode and do not replace ORP calibration. The free chlorine electrode is used with its own electrolyte gel and membrane parts; when ordering, the solution is chosen by electrode type.
Çilek Havuz Corporate