Pool Disinfection Systems
Heliox Replacement Lamp/Sleeve, UV Replacement Part.
Heliox Replacement Lamp/Sleeve is a spare parts group for replacing the lamps and quartz sleeves of AstralPool Heliox UV MP and UV LP systems. Çilek Havuz supplies Heliox Replacement Lamp · Sleeve through quotes and as part of its projects. The group has 9 parts: 3 MP lamps, 2 MP sleeves, the 90 W UV LP-25 lamp, the UV LP-20/25/30 sleeve, the 340 W UV LP lamp and the 1100 mm quartz sleeve.
CH-DEZ-0040-07

- Heliox UV MP
- 50,80, 140, 300, 450, 675 and automatic wiper models
- List price
- From €231 + VAT
Prices are list prices dated 16.06.2026, excluding VAT.
Suitable pool and installation
Models and price
9 models
List price €231 - €1,942.50 excl. VAT
Lowest list price: UV LP-20/25/30 quartz sleeve (Heliox LP)
List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.
See all models and technical dataCompatibility and connections
- Heliox UV MP
- 50, 80, 140, 300, 450, 675 and automatic wiper models
- Heliox UV LP 90 W
- LP S.S. I45-I95, LP PE P20 EX-P70
- Heliox UV LP 340 W
- LP PE P95-P300, 1100 mm sleeve
- Selection criterion
- Reactor model and unit code
// Models
Heliox Replacement Lamp/Sleeve models, with list prices and technical data.
9 products
Heliox UV MP 50/80 lamp
Code CH-DEZ-0040-01
- Compatibility
- 52200 / 52201 / 58808 / 58809
Price€1,417.50 + VATHeliox UV MP 140 lamp
Code CH-DEZ-0040-02
- Compatibility
- 52202 / 58698
Price€1,522.50 + VATHeliox UV MP 300/450/675 lamp
Code CH-DEZ-0040-03
- Compatibility
- 52203 / 52204 / 52205 / 58810 / 58699 / 58811
Price€1,942.50 + VATHeliox MP 50/80/140 quartz sleeve
Code CH-DEZ-0040-04
- Compatibility
- Heliox MP 50 / 80 / 140
Price€325 + VATHeliox MP 300/450/675 quartz sleeve
Code CH-DEZ-0040-05
- Compatibility
- Heliox MP 300 / 450 / 675
Price€388.50 + VAT90W UV LP-25 lamp (Heliox LP)
Code CH-DEZ-0040-06
- Compatibility
- 60344 / 60345 / 60346 / 60347 / 63138 / 63139 / 63140 / 60348 / 60349 / 60354 / 60358
Price€414.75 + VATUV LP-20/25/30 quartz sleeve (Heliox LP)
RecommendedCode CH-DEZ-0040-07
- Compatibility
- 60344 / 60345 / 60346 / 60347 / 63138 / 63139 / 63140 / 60348 / 60349 / 60354 / 60358
Price€231 + VAT340W UV LP lamp
Code CH-DEZ-0040-08
- Compatibility
- 63135 / 63136 / 64347 / 64348 / 64349 / 63137
Price€724.50 + VATUV LP 1100mm quartz sleeve
Code CH-DEZ-0040-09
- Compatibility
- 63135 / 63136 / 64347 / 64348 / 64349 / 63137
Price€630 + VAT
// 01 · Technical table
Heliox Replacement Lamp/Sleeve technical values
Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.
| Specification | Value |
|---|---|
| Manufacturer Code | 60638 / 60639 / 60642 / 60643 / 60644 / 60609 / 60631 / 66062 / 66063 |
| Compatibility | 52200 / 52201 / 58808 / 58809 / 52202 / 58698 / 52203 / 52204 / 52205 / 58810 / 58699 / 58811 / Heliox MP 50 / 80 / 140 / Heliox MP 300 / 450 / 675 / 60344 / 60345 / 60346 / 60347 / 63138 / 63139 / 63140 / 60348 / 60349 / 60354 / 60358 / 63135 / 63136 / 64347 / 64348 / 64349 / 63137 |
| UV Lamp Power | 90 W / 340 W (on some models) |
// 02 · Use
Users and applications
Replacement lamps and sleeves are used in Heliox reactors whose UV-C output has dropped or whose lamp hours have run out. Heliox UV MP uses a medium pressure lamp; the lamp is chosen by the MP model number. Heliox UV LP uses a low pressure lamp; models from P20 EX to P70 and the stainless S.S. models take a 90 W lamp, models from P95 to P300 a 340 W lamp.
- Heliox UV LP reactors that have reached their lamp hours
- Heliox UV MP units whose UV-C sensor value has dropped
- Quartz sleeves that have cracked or hold permanent scale
- Heliox systems with a known reactor model and unit code
// 03 · Installation and compatibility
Installation and compatible equipment
Before replacement, the reactor is de-energised and the lamp is left to cool. The old lamp is pulled out of the quartz sleeve. The new lamp is fitted without touching its glass surface with bare hands. If the sleeve is being replaced, the seals are renewed as well. After start-up, the lamp counter is checked on LP models and the UV-C sensor value on MP models.
- The reactor model and unit code are read, and the lamp and sleeve are selected.
- The power is switched off and the lamp is left to cool.
- The old lamp is pulled out of the sleeve.
- The new lamp is fitted wearing gloves; if necessary, the sleeve and seals are renewed.
- The reactor is started and the counter or UV-C value is checked.
// 04 · Maintenance
Maintenance checkpoints
In a UV system, efficiency depends as much on the cleanliness of the quartz sleeve as on the age of the lamp. A dirty or scaled sleeve blocks UV-C radiation before it reaches the water. The sleeve is removed and cleaned at every lamp replacement. On Heliox UV MP models with automatic wiper, the sleeve surface is wiped during operation; on models without a wiper, cleaning is done by hand.
- The lamp counter is monitored and lamp replacement is planned.
- The quartz sleeve is cleaned of scale and dirt.
- The sleeve seals are checked during lamp replacement.
- On MP models, the UV-C sensor value is read regularly.
// 05 · Information form
Request information on this product
Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form
Heliox Replacement Lamp/Sleeve
- Product
- Heliox Replacement Lamp/Sleeve
- Category
- Pool Disinfection Systems
- Number of models
- 9
- Code
- CH-DEZ-0040-01 ... CH-DEZ-0040-09
Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.
Your contact details
Name, surname, phone and email are enough.
// 06 · Reviews
Heliox Replacement Lamp/Sleeve reviews
If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.
Average rating
0/5
Verified reviews: 0
- 5 out of 5 stars
- 0
- 4 out of 5 stars
- 0
- 3 out of 5 stars
- 0
- 2 out of 5 stars
- 0
- 1 out of 5 stars
- 0
Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.
There are no verified reviews for this product yet. Be the first to write one.
Write a review// 07 · Related products
Products considered together
First the products in the same family, then the power, connection and control parts it needs to run, and finally the complementary products usually chosen with it.
// 08 · Services
Work carried out with this product
Heliox Replacement Lamp/Sleeve can be purchased on its own or installed as part of a pool construction or maintenance project.
- Pool MaintenanceWater chemistry, equipment and periodic maintenance.
- Swimming Pool ConstructionReinforced-concrete, prefabricated and infinity swimming pools, built turnkey for villa, residential and commercial projects.
- Pool ConsultingExpert consulting on project, materials and budget.
- Misk 30 · Multi-Unit PoolIstanbul
// 09 · Guides
Selection and installation guides
These articles cover the calculations, comparisons and installation details considered when choosing and installing Heliox Replacement Lamp/Sleeve.
// 10 · Data sheet and catalogue
Printable documents
The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.
- Product details
- Heliox Replacement Lamp/Sleeve
- Model
- 9
- Code
- CH-DEZ-0040-01 - CH-DEZ-0040-09
- Category
- Pool Disinfection Systems
// 11 · Design and catalogues
Set up your project on screen first, then review the products in our catalogues.
In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.
PoolDesign studio
Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.
Where would you like to start?
Product catalogues
Models, technical sheets and list prices of our product groups are on the category pages.
Next step
Let us discuss your project in the way that suits you best.
You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.
Get a Quote
Send us your dimensions and expectations in writing.
Online presentation
Video project presentation
On-site survey
Inspection at your project site
// 12 · Company & Contact
To talk about your project, call or write to us.
Legal Name
Çilek Havuz
Founded
1998 · Istanbul
Head Office
Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul
Service Area
All of Türkiye · exports to 14 countries
Branches
Kyrgyzstan · Egypt · Algeria · Iraq
Showroom
Plan a showroom visit
At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.
Working Hours
- Monday – Friday · 08:00 – 17:30
- Saturday · 08:00 – 12:30
- Closed on Sunday
Questions
About Heliox Replacement Lamp/Sleeve: frequently asked questions
Çilek Havuz Corporate
Pool & Wellness Engineering
- Response Time
- Same day
- Channels
- Phone · Email · WhatsApp
If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.
+90 216 475 39 37The MP lamp is chosen by the model number of the reactor. The Heliox UV MP 50/80 lamp is used for MP 50 and MP 80, and the Heliox UV MP 140 lamp for MP 140. The Heliox UV MP 300/450/675 lamp is fitted to MP 300, MP 450 and MP 675. Models with automatic wiper use the same lamps.
Çilek Havuz Corporate
The 90 W UV LP-25 lamp fits Heliox UV LP S.S. I45-I95 models and LP PE P20 EX-P70 models. The sleeve for these models is the UV LP-20/25/30 quartz sleeve. LP PE P95, P140, P180, P220, P260 and P300 models use the 340 W UV LP lamp and the 1100 mm quartz sleeve.
Çilek Havuz Corporate
The quartz sleeve is replaced when it cracks or holds scale and stains that cleaning cannot remove. The sleeve is the glass jacket that separates the lamp from the water, and UV-C radiation passes through this glass. A clouded sleeve weakens disinfection even when the lamp is new. The sleeve is removed and checked at every lamp replacement.
Çilek Havuz Corporate
Yes, Heliox UV MP models with automatic wiper use the same lamp and sleeve groups. For MP 50, MP 80 and MP 140, the Heliox MP 50/80/140 quartz sleeve is chosen. For MP 300, MP 450 and MP 675, the Heliox MP 300/450/675 quartz sleeve is used. The wiper slows down how quickly the sleeve gets dirty.
Çilek Havuz Corporate
Heliox Replacement Lamp/Sleeve covers the lamps and sleeves of Heliox UV MP and Heliox UV LP reactors; it does not include electrodes. Neolysis Spare Parts covers the lamps, sleeves and electrodes of the AstralPool Neolysis S unit. The 90 W UV LP-25 lamp and the UV LP-20/25/30 quartz sleeve are the same part in both groups.
Çilek Havuz Corporate
When replacing a UV lamp, the power is first switched off and the lamp is left to cool. The glass surface of the new lamp is not touched with bare hands; fingerprints reduce radiation. The sleeve seals are checked and renewed if necessary. After start-up, the lamp counter is reset on LP models and the UV-C sensor value is read on MP models. Leaks are also checked.
Çilek Havuz Corporate
The MP 50 and MP 80 lamp fits units with codes 52200, 52201, 58808 and 58809. The MP 140 lamp is fitted to units with codes 52202 and 58698. The MP 300, MP 450 and MP 675 lamp fits units with codes 52203, 52204, 52205, 58810, 58699 and 58811. Before ordering, the unit code is compared with this list.
Çilek Havuz Corporate