Pool Disinfection Systems
Salt Chlorinator Replacement Electrodes, Chlorinator Cell.
The Salt Electrolysis Spare Electrode is a chlorine production cell fitted in place of a worn electrode in public pool salt chlorinators. Çilek Havuz supplies Spare Electrodes through quotes and as part of its projects. The page lists 19 models: 6 electrodes for Pro-Chlore Salt, 5 for Nature Salt, 4 for Easy Salt and 4 for Easy Salt Next. Each electrode is chosen according to the capacity of the unit and fits only that model.
CH-DEZ-0038-12

- Compatible series
- Pro-Chlore Salt, Nature Salt, Easy Salt, Easy Salt Next
- List price
- From €3,412.50 + VAT
Prices are list prices dated 16.06.2026, excluding VAT.
Suitable pool and installation
Models and price
19 models
List price €3,412.50 - €30,975 excl. VAT
Lowest list price: Easy Salt 50/EXT-1 electrode
List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.
See all models and technical dataCompatibility and connections
- Compatible series
- Pro-Chlore Salt, Nature Salt, Easy Salt, Easy Salt Next
- Selection criterion
- Unit capacity (g/h) and series name
- Version
- Standard, EXT-1 and EXT-2 use the same electrode
- Cell life
- 10,000 to 15,000 hours, depending on series
// Models
Salt Chlorinator Replacement Electrodes models, with list prices and technical data.
19 products
Pro-Chlore Salt A-50EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-01
Price€4,462.50 + VATPro-Chlore Salt A-80EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-02
Price€6,877.50 + VATPro-Chlore Salt A-120EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-03
Price€10,237.50 + VATPro-Chlore Salt A-180EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-04
Price€15,952.50 + VATPro-Chlore Salt A-300EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-05
Price€28,980 + VATPro-Chlore Salt A-600EX/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-06
Price€29,715 + VATNature Salt A-50EX/LS/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-07
Price€9,975 + VATNature Salt A-80EX/LS/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-08
Price€15,750 + VATNature Salt A-120EX/LS/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-09
Price€20,265 + VATNature Salt A-180EX/LS/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-10
Price€27,300 + VATNature Salt A-300EX/LS/EXT-1/EXT-2 electrode
Code CH-DEZ-0038-11
Price€30,975 + VATEasy Salt 50/EXT-1 electrode
RecommendedCode CH-DEZ-0038-12
Price€3,412.50 + VATEasy Salt 70/EXT-1 electrode
Code CH-DEZ-0038-13
Price€4,567.50 + VATEasy Salt 90/EXT-1 electrode
Code CH-DEZ-0038-14
Price€5,775 + VATEasy Salt 180/EXT-1 electrode
Code CH-DEZ-0038-15
Price€11,025 + VATEasy Salt Next 75 pH/ORP electrode
Code CH-DEZ-0038-16
Price€4,336.50 + VATEasy Salt Next 100 pH/ORP electrode
Code CH-DEZ-0038-17
Price€4,977 + VATEasy Salt Next 150 pH/ORP electrode
Code CH-DEZ-0038-18
Price€7,245 + VATEasy Salt Next 190 pH/ORP electrode
Code CH-DEZ-0038-19
Price€8,190 + VAT
// 01 · Technical table
Salt Chlorinator Replacement Electrodes technical values
Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.
| Specification | Value |
|---|---|
| Manufacturer Code | 60634 / 60636 / 60676 / 60677 / 60678 / 60679 / 60680 / 60681 / 60682 / 60683 / 60684 / 68104 / 60685 / 60686 / 60687 / 73339 / 73340 / 73341 / 73342 |
// 02 · Use
Users and applications
The spare electrode is replaced in a salt chlorinator whose chlorine output has fallen or that has completed its operating hours. The unit body is kept; only the cell is renewed. The correct electrode is found from the series name and capacity on the unit label. Pro-Chlore Salt and Nature Salt electrodes are EX type; Nature Salt electrodes also work with low-salt LS units.
- Chlorinators whose chlorine output has fallen noticeably
- Cells that have completed their operating hours (10,000 to 15,000 hours)
- Electrodes with wear or permanent scale on their plates
- Units whose series name and capacity on the label are known
// 03 · Installation and compatibility
Installation and compatible equipment
Before replacement, the power to the unit is switched off. The electrode is chosen from the model that matches the series name and capacity on the unit label, and fitted to the cell following the manufacturer's replacement instructions. When the old electrode is removed, the cable connection is disconnected, and the new one is seated in the same position. After fitting, the unit is checked for leaks; the hour counter and output value of the unit are monitored again.
- The series name and capacity are read from the unit label and the electrode is chosen.
- The power to the unit is switched off and the cell line is closed.
- The cable connection is disconnected and the old electrode is removed.
- The new electrode is seated and connected.
- The line is opened, and leaks and chlorine output are checked.
// 04 · Maintenance
Maintenance checkpoints
Electrode life is determined by the salt level, water hardness and operating hours. The salt level is kept within the range recommended for the unit: 5 to 12 g/l for Easy Salt and Pro-Chlore Salt, 1.5 to 3 g/l for Nature Salt. If scale is seen on the plates, it is dissolved following the cleaning instructions of the unit. Running with low salt wears the plates quickly.
- The salt level is kept within the range for the series.
- The plates are checked periodically for scale.
- The operating hour counter of the unit is monitored.
- The pH is kept in balance to reduce scale formation.
// 05 · Information form
Request information on this product
Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form
Salt Chlorinator Replacement Electrodes
- Product
- Salt Chlorinator Replacement Electrodes
- Category
- Pool Disinfection Systems
- Number of models
- 19
- Code
- CH-DEZ-0038-01 ... CH-DEZ-0038-19
Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.
Your contact details
Name, surname, phone and email are enough.
// 06 · Reviews
Salt Chlorinator Replacement Electrodes reviews
If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.
Average rating
0/5
Verified reviews: 0
- 5 out of 5 stars
- 0
- 4 out of 5 stars
- 0
- 3 out of 5 stars
- 0
- 2 out of 5 stars
- 0
- 1 out of 5 stars
- 0
Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.
There are no verified reviews for this product yet. Be the first to write one.
Write a review// 07 · Related products
Products considered together
First the products in the same family, then the power, connection and control parts it needs to run, and finally the complementary products usually chosen with it.
// 08 · Services
Work carried out with this product
Salt Chlorinator Replacement Electrodes can be purchased on its own or installed as part of a pool construction or maintenance project.
- Pool MaintenanceWater chemistry, equipment and periodic maintenance.
- Swimming Pool ConstructionReinforced-concrete, prefabricated and infinity swimming pools, built turnkey for villa, residential and commercial projects.
- Pool ConsultingExpert consulting on project, materials and budget.
- Misk 30 · Multi-Unit PoolIstanbul
// 09 · Guides
Selection and installation guides
These articles cover the calculations, comparisons and installation details considered when choosing and installing Salt Chlorinator Replacement Electrodes.
// 10 · Data sheet and catalogue
Printable documents
The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.
- Product details
- Salt Chlorinator Replacement Electrodes
- Model
- 19
- Code
- CH-DEZ-0038-01 - CH-DEZ-0038-19
- Category
- Pool Disinfection Systems
// 11 · Design and catalogues
Set up your project on screen first, then review the products in our catalogues.
In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.
PoolDesign studio
Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.
Where would you like to start?
Product catalogues
Models, technical sheets and list prices of our product groups are on the category pages.
Next step
Let us discuss your project in the way that suits you best.
You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.
Get a Quote
Send us your dimensions and expectations in writing.
Online presentation
Video project presentation
On-site survey
Inspection at your project site
// 12 · Company & Contact
To talk about your project, call or write to us.
Legal Name
Çilek Havuz
Founded
1998 · Istanbul
Head Office
Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul
Service Area
All of Türkiye · exports to 14 countries
Branches
Kyrgyzstan · Egypt · Algeria · Iraq
Showroom
Plan a showroom visit
At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.
Working Hours
- Monday – Friday · 08:00 – 17:30
- Saturday · 08:00 – 12:30
- Closed on Sunday
Questions
About Salt Chlorinator Replacement Electrodes: frequently asked questions
Çilek Havuz Corporate
Pool & Wellness Engineering
- Response Time
- Same day
- Channels
- Phone · Email · WhatsApp
If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.
+90 216 475 39 37The electrode is replaced when chlorine output has fallen noticeably or when the cell has reached the end of its life. Cell life is 10,000 to 12,000 hours on Easy Salt and Easy Salt Next VC units. On Pro-Chlore Salt and Nature Salt units it is 12,000 to 15,000 hours. If the salt level is correct and output is still low, the electrode is checked.
Çilek Havuz Corporate
The electrode is matched to the series name and capacity of the unit. The unit label reads, for example, Pro-Chlore Salt A-80EX or Easy Salt 90; the electrode with the same name and capacity is chosen. An electrode of a different capacity is not fitted to the unit and is not used. If the series name cannot be read, the manufacturer code of the unit is used.
Çilek Havuz Corporate
Yes, standard, EXT-1 and EXT-2 units of the same capacity use the same electrode. For example, the Pro-Chlore Salt A-120EX electrode fits the A-120EX, A-120EX EXT-1 and EXT-2 units. The EXT versions differ only in their pH and ORP or ppm control hardware. The capacity and series name are sufficient for choosing the electrode.
Çilek Havuz Corporate
No, electrodes are not interchangeable between series. Nature Salt works with low salt, in the 1.5 to 3 g/l range; Pro-Chlore Salt uses 5 to 12 g/l of salt. The electrode of each series is made for its own salt range. Even though they carry the same capacity number, the Nature Salt A-50 electrode does not fit the Pro-Chlore Salt A-50EX unit.
Çilek Havuz Corporate
The Salt Electrolysis Spare Electrode page covers the Pro-Chlore Salt, Nature Salt, Easy Salt and Easy Salt Next electrodes. The electrodes of the AstralPool Neolysis S unit, on the other hand, are on the Neolysis Spare Parts page together with UV lamps and the quartz chamber. Neolysis S electrodes are offered in 5 capacities between 50 and 300 g/h.
Çilek Havuz Corporate
Electrode life is extended by keeping the salt level and pH in balance. Low salt wears the plates quickly, while high pH causes scale to build up on the plates. The unit is not run at an output setting higher than the pool requires. When scale is seen on the plates, the cleaning instructions of the unit are followed and the salt level is measured again.
Çilek Havuz Corporate
For Easy Salt there are EXT-1 compatible electrodes for the 50, 70, 90 and 180 models. For Easy Salt Next there are electrodes for the 75, 100, 150 and 190 pH/ORP models. The electrode is matched to the model of the unit. Easy Salt series electrodes do not fit Pro-Chlore Salt or Nature Salt units.
Çilek Havuz Corporate


