Victoria Plus Silent is a self-priming, single speed pool pump connected to the filtration line of pools. Çilek Havuz supplies Victoria Plus Silent through quotes and as part of its projects. Its five sizes, in single-phase M and three-phase T versions, deliver 11-35 m³/h nominal flow and 0.56-2.24 kW motor power. Connections vary between D50, D63 and D75. The motor is IP55 protected and the pre-filter housing comes mounted on the body.

Datasheet

CH-POM-0006-01

Victoria Plus Silent at an angle, motor on the left, black body in the centre
Nominal Flow (Qn)
11-35m³/h
Rated Power (P2N)
0.56-2.24kW
Connection
D50, D63 or D75
List price
From €640.50 + VAT

Prices are list prices dated 16.06.2026, excluding VAT.

Before you choose

Suitable pool and installation

Models and price

10 models

List price €640.50 - €892.50 excl. VAT

Lowest list price: 75M

List price, excluding VAT. The final figure depends on quantity and scope and is given in the quotation.

Open the spec sheet
See all models and technical data

Compatibility and connections

Connection
D50, D63 or D75
Power supply
230 V single-phase or 230-400 V three-phase
Protection class
IP55
Operation
Single speed

// Models

Victoria Plus Silent models, with list prices and technical data.

10 products

  • 75M

    Recommended

    Code CH-POM-0006-01

    Nominal Flow (Qn)
    11 m³/h
    Rated Power (P2N)
    0.56 kW
    Connection
    D50 mm
    Price€640.50 + VAT

    75M

    Code CH-POM-0006-01

    €640.50 + VAT

    Manufacturer Code
    65560
    Voltage
    230 V
    Nominal Flow (Qn)
    11 m³/h
    Nominal head (HN)
    10 m
    Max. Head (Hmax)
    15 m
    Max. Flow (Qmax)
    18 m³/h
    Rated Power (P2N)
    0.56 kW
    Max. Power (Pmax)
    0.72 kW
    Connection
    D50 mm
    Noise Level
    61 - 70 dBA
    Protection Class (IP)
    IP55
    Weight
    13 kg
  • 75T

    Code CH-POM-0006-06

    Nominal Flow (Qn)
    11 m³/h
    Rated Power (P2N)
    0.56 kW
    Connection
    D50 mm
    Price€640.50 + VAT
  • 100M

    Code CH-POM-0006-02

    Nominal Flow (Qn)
    16 m³/h
    Rated Power (P2N)
    0.75 kW
    Connection
    D50 mm
    Price€666.75 + VAT
  • 100T

    Code CH-POM-0006-07

    Nominal Flow (Qn)
    16 m³/h
    Rated Power (P2N)
    0.75 kW
    Connection
    D50 mm
    Price€666.75 + VAT
  • 150M

    Code CH-POM-0006-03

    Nominal Flow (Qn)
    21.5 m³/h
    Rated Power (P2N)
    1.12 kW
    Connection
    D63 mm
    Price€750.75 + VAT
  • 150T

    Code CH-POM-0006-08

    Nominal Flow (Qn)
    21.5 m³/h
    Rated Power (P2N)
    1.12 kW
    Connection
    D63 mm
    Price€750.75 + VAT
  • 200M

    Code CH-POM-0006-04

    Nominal Flow (Qn)
    26 m³/h
    Rated Power (P2N)
    1.49 kW
    Connection
    D63 mm
    Price€766.50 + VAT
  • 200T

    Code CH-POM-0006-09

    Nominal Flow (Qn)
    26 m³/h
    Rated Power (P2N)
    1.49 kW
    Connection
    D63 mm
    Price€766.50 + VAT
  • 300M

    Code CH-POM-0006-05

    Nominal Flow (Qn)
    35 m³/h
    Rated Power (P2N)
    2.24 kW
    Connection
    D75 mm
    Price€892.50 + VAT
  • 300T

    Code CH-POM-0006-10

    Nominal Flow (Qn)
    35 m³/h
    Rated Power (P2N)
    2.24 kW
    Connection
    D75 mm
    Price€892.50 + VAT

// 01 · Technical table

Victoria Plus Silent technical values

Where a value changes from model to model, every option is listed in that row; the details for each model are in the model list below.

Victoria Plus Silent technical values · 10 models
SpecificationValue
Manufacturer Code65560 / 65561 / 65562 / 65563 / 65564 / 65565 / 65566 / 65567 / 65569 / 65570
Voltage230 V / 230 / 400 V
Nominal Flow (Qn)11 m³/h / 16 m³/h / 21.5 m³/h / 26 m³/h / 35 m³/h
Nominal head (HN)10 m
Max. Head (Hmax)15 m / 17 m / 18 m / 21 m
Max. Flow (Qmax)18 m³/h / 23.5 m³/h / 29 m³/h / 33.5 m³/h / 41 m³/h
Rated Power (P2N)0.56 kW / 0.75 kW / 1.12 kW / 1.49 kW / 2.24 kW
Max. Power (Pmax)0.72 kW / 0.98 kW / 1.02 kW / 1.40 kW / 1.80 kW / 2.59 kW / 2.40 kW
ConnectionD50 mm / D63 mm / D75 mm
Noise Level61 - 70 dBA
Protection Class (IP)IP55
Weight13 kg / 14 kg / 17 kg / 18 kg / 19 kg / 23 kg

// 02 · Use

Users and applications

Victoria Plus Silent is chosen as the circulation pump that passes pool water through the filter and pushes it back to the pool. The size is set by the flow required by the filtration line: the smallest 75 model delivers 11 m³/h and the largest 300 model 35 m³/h nominal flow. Weight is between 13 and 23 kg; noise stays within 61 to 70 dBA.

  • Pool filtration lines
  • Plant rooms with D50, D63 or D75 pipework
  • T versions for buildings with a three-phase supply
  • Single speed circulation set-ups

// 03 · Installation and compatibility

Installation and compatible equipment

Victoria Plus Silent is fitted between the suction line coming from the pool and the filter; PVC fitting accessories are included in the package. As the pre-filter housing comes mounted on the body, no separate pre-filter is needed. M models are connected to a 230 V single-phase line, T models to a 230-400 V three-phase line. The supply can be taken through the Electrical Control Panel. The discharge outlet goes to the Multiport Valve inlet of a filter such as the Aster Sand Filter.

  1. The pump is placed on a level, dry surface in front of the filter.
  2. The suction line is connected to the front connection and the discharge outlet to the Multiport Valve inlet of the filter.
  3. The housing is filled with water through the transparent lid and the two-handle lid is closed.
  4. The supply is taken through the Electrical Control Panel or through motor protection suited to the phase.

// 04 · Maintenance

Maintenance checkpoints

Routine work consists of removing leaves and debris collected in the pre-filter housing while the pump is switched off. The two-handle lid opens by hand without a tool. After the housing is cleaned, the lid is seated back in place and closed. If there is a noticeable change in the operating sound, the suction line and the housing are checked.

  • The pre-filter housing is opened and cleaned while the pump is switched off.
  • The suction line is checked for air leaks.
  • The connection unions are checked for leaks.

// 05 · Information form

Request information on this product

Leave your name and contact details, and your customer representative will get back to you about the models of this product, its fit for your pool and an up-to-date quote.

Subject of the form

Victoria Plus Silent

Product
Victoria Plus Silent
Category
Pool Mechanical Equipment
Number of models
10
Code
CH-POM-0006-01 ... CH-POM-0006-10

Your request is recorded under the name of this product. If you prefer not to wait, you can also reach us on +90 216 475 39 37.

Your contact details

Name, surname, phone and email are enough.

Your personal data is processed in line with our Privacy Notice (KVKK).

// 06 · Reviews

Victoria Plus Silent reviews

If you use this product or have used our service for it, share your experience. Every review is published after our team verifies it, and ratings are calculated from verified reviews only.

Average rating

0/5

Verified reviews: 0

5 out of 5 stars
0
4 out of 5 stars
0
3 out of 5 stars
0
2 out of 5 stars
0
1 out of 5 stars
0

Reviews are verified and published by the Çilek Havuz team. A product review covers the product itself; a service review covers delivery, installation and communication.

There are no verified reviews for this product yet. Be the first to write one.

Write a review

Write a review

Once verified, your review is published with your name and city. Your email or phone number is never published.

Your rating

What is your review about?

Not published; used only to verify your review.

Your personal data is processed in line with our Privacy Notice (KVKK).

// 09 · Guides

Selection and installation guides

These articles cover the calculations, comparisons and installation details considered when choosing and installing Victoria Plus Silent.

// 10 · Data sheet and catalogue

Printable documents

The technical data sheet is a single A4 page. The product catalogue brings together the cover, images, model list and technical table.

Product details
Victoria Plus Silent
Model
10
Code
CH-POM-0006-01 - CH-POM-0006-10

// 11 · Design and catalogues

Set up your project on screen first, then review the products in our catalogues.

In the design studio you can build your space with its materials and colours; in the product catalogues you can see models, technical sheets and list prices.

Long villa pool with a travertine edge and olive trees at sunsetPool

Design studio

Build your pool, sauna, steam room or Turkish hammam on screen with lining, timber and marble options, then request a quote with your selection.

Where would you like to start?

Next step

Let us discuss your project in the way that suits you best.

You can fill in the form for a written quote, schedule a video project presentation or ask us to survey your project site.

  • Get a Quote

    Send us your dimensions and expectations in writing.

  • Online presentation

    Video project presentation

  • On-site survey

    Inspection at your project site

// 12 · Company & Contact

To talk about your project, call or write to us.

Legal Name

Çilek Havuz

Founded

1998 · Istanbul

Head Office

Çilek Plaza, Eyüp Sultan Mah. Yakacık Cd. Feshane Cd. No: 2 D:4 D:1, 34885 Sancaktepe / İstanbul

Service Area

All of Türkiye · exports to 14 countries

Branches

Kyrgyzstan · Egypt · Algeria · Iraq

Showroom

Plan a showroom visit

At our showroom in Çilek Plaza, Sancaktepe, you can discuss your project with our team. We recommend booking an appointment by phone before your visit.

Working Hours

  • Monday – Friday · 08:00 – 17:30
  • Saturday · 08:00 – 12:30
  • Closed on Sunday
Directions

Questions

About Victoria Plus Silent: frequently asked questions

Çilek Havuz Corporate

Pool & Wellness Engineering

Response Time
Same day
Channels
Phone · Email · WhatsApp

If the answer you are looking for is not here, send your question directly to us and our team will reply as soon as possible.

+90 216 475 39 37

The model is chosen by the flow required by the filtration line. The 75 model delivers 11 m³/h, the 100 model 16 m³/h, the 150 model 21.5 m³/h, the 200 model 26 m³/h and the 300 model 35 m³/h nominal flow. The required flow is found by dividing the pool volume by the turnover time; for a residential pool, the turnover time is 4 to 6 hours.

Çilek Havuz Corporate

The choice is set by the building's electrical supply. M versions are connected to a 230 V single-phase line and T versions to a 230-400 V three-phase line. Every size is available in both M and T versions. M and T models with the same number have the same nominal flow and motor power; the maximum power drawn differs slightly on some sizes.

Çilek Havuz Corporate

Victoria Plus Silent delivers 11-35 m³/h in five sizes and has a two-handle, tool-free pre-filter lid. Verdon ES starts at 7.0 m³/h with the 50M and rises to 31 m³/h on the 300 model. If a small pool needs 7.0 or 10.5 m³/h, Verdon ES is chosen; for a wider flow range and 35 m³/h, Victoria Plus Silent is chosen.

Çilek Havuz Corporate

The connection diameter depends on size. The 75 and 100 models have D50, the 150 and 200 models D63 and the 300 model D75 connections. PVC fitting accessories are included in the package. If the diameter of the existing pipework is known, the choice is first narrowed by this diameter and then by flow.

Çilek Havuz Corporate

The noise level is within 61 to 70 dBA and depends on size. The pump is designed for low-noise operation. As it is single speed, noise stays constant during operation and cannot be reduced by changing speed. If speed adjustment is needed, the variable speed Victoria Plus Silent VS is chosen; the VS 100 gives 45 dBA at the low step.

Çilek Havuz Corporate

The difference is speed control. Victoria Plus Silent is single speed; its 10 models deliver 11-35 m³/h. Victoria Plus Silent VS is variable speed; its two models deliver 17.0 and 26.0 m³/h, and it has a built-in display and timer. The Electrical Control Panel is used with the single speed pump.

Çilek Havuz Corporate

As the lid has two handles, no tool is needed and it opens by hand. Cleaning is done with the pump switched off. As the lid is transparent, the level of the housing can be seen from outside. The pre-filter housing comes mounted on the body and prevents foreign matter from entering the hydraulic parts of the pump. After cleaning, the lid is seated back in place; the housing is filled with water before the pump is restarted.

Çilek Havuz Corporate